Choose a material

Roofing sheets

Blachy trapezowe

Sandwich panels

Płyty warstwowe

PIR insulation boards

Płyty izolacyjne PIR

XPS

Izolacja XPS

Accessories

Akcesoria montażowe

Fencing

Sztachety metalowe

Choosing wall and roof sandwich panels for a steel building

Steel buildings and structures

At a glance

A sandwich panel combines metal facings with an insulating core. To specify panels for a warehouse, factory or agricultural building, start with the conditions on each side of the envelope: temperature, moisture, loads and use. Wall systems can have exposed or concealed fasteners and may allow vertical or horizontal installation. Roof panels are shaped and jointed to shed water and carry loads on a slope; many have a trapezoidal outer facing. Matching thickness does not make a wall panel suitable for a roof. Select the actual product together with its supports, fasteners and joint details.

Steel building with light-coloured sandwich panel walls and blue flashings

Wall and roof panels serve different purposes

Specify a panel type for each application. Check its load capacity for the actual loads, span, supports, number of spans and fixings. Frame and envelope must be coordinated: changing the purlin spacing can change whether the same roof panel is suitable.

Choose the core for the building’s use

PIR can provide high thermal resistance in a relatively thin panel. Mineral wool panels are often considered where fire performance matters and can also meet particular acoustic requirements. Compare the declared performance of the complete panels, not just the names of the cores.

A heated building needs an envelope suited to its operating temperature and energy requirements. Priorities may differ in an unheated store, but condensation and the conditions needed by the goods still matter. An insulated shell does not provide heating, cooling or ventilation by itself.

Reaction to fire and fire resistance are different

Reaction to fire describes how a product contributes to fire development. Fire resistance concerns the performance of a building element over a specified time. A non-combustible core alone does not establish the resistance of a wall. Check the classification of the actual assembly and its field of application.

Panel thickness, span, installation direction, supports and joints can all affect the classification. Service penetrations need suitable details. Check the loadbearing frame separately: a fire resistance rating for a panel does not give columns and rafters that same rating.

Gabled steel frame from the SteelProfil modular building range – free quote

Airtightness depends on the junctions

A good panel insulation value will not compensate for air leaking through joints. Check corners, the wall base, ridge and surrounds of windows and doors. Select gaskets, tapes and flashings for the specific system. Filling a gap with whatever is on hand is no substitute for a detailed junction.

Keep insulation continuous and seal junctions between building elements. The design should limit thermal bridges and installation should preserve the intended layer sequence. This matters in farm buildings too: moisture from crops or processes needs both a suitable envelope and controlled ventilation.

Check the roof as a complete system

Obtain the minimum pitch for the selected roof panel system. End laps, rooflights and other details can affect the requirement; no single pitch applies to every panel. Include roof drainage, snow loads and wind actions in the building design.

Choose fasteners for the substrate, load and position on the roof. Edge and corner zones can require a different fixing pattern from the central area. Do not support rooftop equipment on the cladding alone without verifying capacity. This applies to kit buildings too.

Handling and maintenance affect service life

Protect facings and joint edges when unloading and lifting. Use tools specified by the panel manufacturer. Remove drilling and cutting swarf: particles left on the surface can rust and stain it. Peel off the protective film within the product-specific time limit.

Once the building is in use, inspect flashings, seals and coatings. Match the cleaning method to the facing and the contamination. Aggressive production environments may need a specially resistant coating. Long-term performance depends on coordinating the frame, panels, fasteners and maintenance regime.

Colour affects panel movement

Dark facings heat up more in sunlight. A temperature difference across a panel affects its deformation, so colour matters when checking panel length, supports and fixings. If a light façade is changed to a dark one before delivery, ask the designer and supplier to confirm the selection again.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide