Powerroof above the rafters: how much roof does one board cover?

PIR insulation

At a glance

For over-rafter Powerroof insulation, count boards by their covering dimensions, not their transport size. A 2400 × 1200 mm board covers 2380 × 1180 mm once the tongue and groove engage: about 2.81 m² per full board in the main roof area. Valleys, chimneys and windows change the yield. Draw rows and cuts for each slope before ordering. Also check an eaves section: over-rafter insulation preserves loft headroom but changes the level of the covering and its terminations.

Recticel Powerroof insulation board showing the core and facing

Where the board fits in the project

Measure the slope along its surface. The loft’s horizontal plan area is not the pitched roof area and will not give the number of rows.

Mark tongue and groove directions on the layout. A rotated offcut may fit in size but have the wrong edge for the next row.

Details to agree with the installer

One board’s outer rectangle is 2.88 m². Price installed roof area using the effective coverage, then add cutting waste separately.

At valleys and windows, do not assume two triangular offcuts are interchangeable. Have the roofer mark the support at cut edges.

Reading the thermal figures

Powerroof’s declared conductivity is 0.022 W/(m·K). Select thickness for the required resistance, then check the resulting covering level.

Fixings passing through the boards also enter the whole-roof assessment. The value for PIR alone is not the roof U-value.

Moisture and substrate condition

Distinguish the drainage layer from the aluminium facing on the drawing. Water diverted around a window must return to the intended drainage plane.

Agree the eaves sequence and temporary rain protection for the exposed slope. The board joint alone is not temporary roofing.

What to check beyond conductivity

Powerroof lists CS(10/Y)150 and reaction to fire D-s2,d0. One describes compression; the other describes fire behaviour under the classification conditions.

Neither value specifies screw length or spacing. Transmission of dead and wind loads from covering to rafters needs its own fixing design.

Quotation and handover

Itemise net cover, whole boards and layout waste. This makes it easier to check the delivery without opening every pallet.

Price changes to flashings and window work separately. Quotes for identical board counts may cover quite different roof-edge work.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide