BauderPIR FA on a house roof: converting board sizes into an order
PIR insulation
A large BauderPIR FA board has two relevant dimensions. Transport and storage use the overall 2400 × 1200 mm size. Set out roof rows using the installed module of 2385 × 1185 mm, which allows for the 15 mm rebate. Whole boards are easy to count in a rectangular field, but the last row at a parapet and cuts at a roof hatch can change the order. Draw these areas and check the route from unloading point to roof before ordering pallets.

What to settle before delivery
Measure the narrowest opening and turn on the access route. If packs will be lifted onto the roof, agree delivery positions suitable for the structure.
Identifying the board and its declared properties
FA has aluminium facings on both sides and a PIR core with declared λD 0.022 W/(m·K). Its rating is CS(10/Y)120 and reaction-to-fire class E. The roofing design determines support and fixing arrangements.
Using a worked example
For twelve whole boards, 12 × 2.400 m × 1.200 m gives 34.56 m² of overall area. Using the installed dimensions, 12 × 2.385 m × 1.185 m gives about 33.91 m² of coverage before cutting.
Mark rooflights and row ends on the same drawing. Allocate larger offcuts to an actual reuse position, allowing for the direction of the remaining rebate.
Comparing the available options
Compare layouts by counting cut boards at the perimeter and measuring narrow strips. Rotating the rows can reduce small cuts along the last edge.
Inspection before covering
Before covering, check that rebates engage along the rows and that damaged corners leave no gap. Missing cuts are easiest to spot at this stage.
What the quote should cover
Record board count, thickness and the area basis in the quote. Price unloading and handling separately, particularly on a narrow driveway or garden access route.
Records to keep after completion
After unloading compare full packs with the delivery schedule. Keep the row plan and actual coverage for settlement so the rebate allowance is not counted again as cutting waste.
Free quote
What to include in your enquiry
Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.
More from the building guide
Changing Eurothane Silver thickness can change more than the insulation value. The 20 mm version has different format options and compressive performance…
The right PIR sandwich-panel thickness for a garage roof depends first on whether the garage will be heated. Thermal requirements, support spacing…
Cost-effective insulation suits the way a building is used. An unheated garage has different needs from a workshop or a holiday cabin…
For a roof with several rooflights, order Therma TR26 from a plan showing the kerb dimensions. Total roof area misses the short…
When the exterior cannot change, termPIR AL GK combines rigid PIR insulation with a 12.5 mm plasterboard lining on the room side.…
To specify Kingspan Therma TT46 tapered boards, trace the water from the high point of the roof to its outlet. Mark the…
Insulation selection starts with its position in the building. A rendered wall, a roof and a continuously loaded floor impose different requirements.…
A roof over an enclosed, heated swimming pool must suit the actual moisture and chemical conditions inside. Insulation thickness or the label…