Therma TT46 on a flat roof: tracing the route to the outlet

PIR insulation

At a glance

To specify Kingspan Therma TT46 tapered boards, trace the water from the high point of the roof to its outlet. Mark the chimney, parapets and actual outlet level on a roof plan. Follow the proposed route on either side of each obstruction: where does each branch discharge? This guide explains how to read the direction and rise of a board, why its thickest edge does not represent the insulation across the whole roof, and which setting-out information the installer needs with the delivery.

Corner of a tapered Kingspan Therma TT46 board showing PIR core and aluminium facing

Start from the outlet level

Start with the surveyed outlet level. If the outlet has moved or its level has changed since the drainage plan was drawn, have the board layout checked against the new position.

Number each run from the ridge to the outlet. An arrow next to each board mark distinguishes the correct fall from a square board laid half a turn out.

Read the rise across one board

TT46 is a foil-faced, square-edged board measuring 1200 × 1200 mm. The height difference between opposite edges is 10, 15, 20 or 25 mm, depending on the taper selected.

A rise of 15 mm over 1.20 m gives 1.25%; 25 mm gives about 2.08%. These are board gradients. The level of the supporting deck also affects the finished fall.

Insulation at the outlet and ridge

The PIR insulation has a declared λD of 0.022 W/(m·K). A thermal assessment needs both the thickness of any base insulation and the changing section of the tapered layer.

Draw a section through the outlet to show the thinnest point. A second section at the ridge reveals the height still available for the waterproofing upstand at the parapet.

Trace the flow past the chimney

Trace both drainage paths behind the chimney until they meet the main roof. Even a correctly oriented taper will not drain freely if the next board presents a raised edge across the flow.

Check the falls before the boards are covered. Watertightness at the valley and outlet flange then depends on the waterproofing detail; the foil facing on TT46 does not form those seals.

Coordinate supports with drainage

TT46 is rated at a compressive stress of at least 120 kPa at 10% deformation and has reaction-to-fire class E. Neither figure gives the permissible bearing pressure under an equipment foot.

If plant is to stand beside the chimney, mark its supports on the drainage plan. The designer can check load transfer and whether the base would obstruct the intended flow path.

Price the marked board layout

For the quotation, supply a dimensioned plan with levels, outlet locations and obstruction sizes. Two roofs of equal area may require different numbers of tapered pieces and cuts.

List base boards separately from the marked TT46 pieces. Check that the price includes the laying plan, cuts around the chimney and the boards needed where the fall changes direction.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide