Choose a material

Roofing sheets

Blachy trapezowe

Sandwich panels

Płyty warstwowe

PIR insulation boards

Płyty izolacyjne PIR

XPS

Izolacja XPS

Accessories

Akcesoria montażowe

Fencing

Sztachety metalowe

Eurofloor beneath underfloor heating: work back from the finished floor level

PIR insulation

At a glance

Before ordering Eurofloor, measure from the base to finished floor level at the lowest threshold. Insulation, heating pipes, screed and finish must share that space. The PIR board limits heat flow downwards; the complete floor section determines whether a given thickness fits. Mark heavy furniture and appliances, and agree how boards will be protected until covered. Pack prices alone tell you little about differences in the proposed floor construction.

Recticel Eurofloor insulation board showing the core and facing

What exactly are you buying?

Set a common finished level for adjoining rooms. Thicker tiles in one room can change the space available even where the doorway must remain level.

Do not size the screed by subtracting an arbitrary board from the threshold height. The pipe-bearing layer must suit the heating system and room loads.

Details to agree with the installer

The Eurofloor sheet lists square 1200 × 1200 mm boards with straight edges. Draw that module on the floor plan before calculating full packs.

At pipe penetrations agree the cut shapes and how they are supported. Loose pieces should not move while the next layer is being laid.

Choosing the thickness for your home

For thicknesses of 20–100 mm Eurofloor has λD 0.022 W/(m·K). The 100 mm board has declared RD 4.50 m²K/W, a board value rather than a floor value.

If a threshold calls for a thinner board, recalculate downward heat loss for that section. Do not carry over the resistance quoted for 100 mm.

Moisture and substrate condition

Identify damp protection and the screed separation layer on the section. The facing restricts diffusion through each board but does not seal the room perimeter.

Inspect continuity at walls and penetrations before the heating pipes go down. Those details become harder to reach afterwards.

What to check beyond conductivity

CS(10/Y)120 describes the compression test at 10% deformation. It does not give the allowable sustained pressure beneath an appliance foot.

The board’s declared reaction-to-fire class is F. Where the project sets requirements for the floor, assess the assembly including screed and finish.

Quotation and handover

Ask for board quantities, separating materials and perimeter work separately. Agree the trade sequence and who protects the exposed insulation.

Before screeding, photograph board and pipe layouts using fixed walls as references. The record can later help locate services without opening the floor.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide