IKO enertherm MG and foil-faced PIR under a synthetic roof membrane
PIR insulation
If a roof quote replaces foil-faced PIR with IKO enertherm MG, ask for a revised section and membrane fixing instructions. MG has coated glass fleece on both faces. The change of facing affects the connection to the covering. The thermal calculation also changes because MG conductivity varies with thickness. Compare the quotations once both state the thickness, declared RD and method of securing each layer. Pay particular attention to details where thicker insulation leaves less height for the membrane upstand.

What to settle before delivery
Record the full membrane designation and identify what secures it. Bonding requires an adhesive compatible with both contact surfaces. Mechanical fixing requires suitable anchorage in the substrate.
Identifying the board and its declared properties
MG’s PIR core is faced with perforated coated glass fleece. Its λD is 0.026 W/(m·K) below 120 mm and 0.025 from 120 mm. The declared compression value is at least 150 kPa and the board has reaction to fire class E.
Using a worked example
Compare the two MG data sheet rows. Declared RD is 3.80 m²K/W at 100 mm and 4.80 m²K/W at 120 mm. The extra 20 mm crosses the boundary between the two conductivity ranges.
Redraw the rooflight kerb if the thickness changes. With an unchanged kerb, the higher roof surface leaves less room for the vertical waterproofing upstand.
Comparing the available options
Request two complete roof options at the same thermal target. Include flashing heights and the fixing specification for the proposed membrane in each.
Inspection before covering
Before laying the membrane, check that the fleece is dry and firmly attached to the core. Mark boards with damaged facings for a repair or replacement decision before covering.
What the quote should cover
Itemise surface preparation, any separation layer required by the system and perimeter fixings. This shows the cost implications of changing the facing.
Records to keep after completion
File the MG label with the membrane designation and instructions for the fixing method actually used. Add photographs of a perimeter junction before the closing layer goes on.
Free quote
What to include in your enquiry
Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.
More from the building guide
PIR boards above the rafters insulate a pitched roof without using up more loft space. Before work begins, agree on the finished…
When choosing IKO enertherm ALU for a house, first establish where the board sits in the assembly and which layers protect it.…
PIR insulated plasterboard combines thermal insulation with an internal wall lining in one product. Its suitability nevertheless depends on wall condition, thermal…
Cost-effective insulation suits the way a building is used. An unheated garage has different needs from a workshop or a holiday cabin…
Before choosing a UNILIN wall board, mark its position on the section. Utherm Wall LE insulates a cavity wall. Wall K Gyp…
Ask what will be finished when the crew leaves. A square metre of PIR does not include substrate preparation, fixings or sealed…
Start a Utherm Roof LE layout at the point where the build-up has least room, often a low access threshold or rooflight…
On IKO enertherm ALU TG boards, the tongue of one board fits into the groove of the next. Along a straight run…