Choose a material

Roofing sheets

Blachy trapezowe

Sandwich panels

Płyty warstwowe

PIR insulation boards

Płyty izolacyjne PIR

XPS

Izolacja XPS

Accessories

Akcesoria montażowe

Fencing

Sztachety metalowe

IDELCO α-therm ROOF: choosing a fixing method for a domestic flat roof

PIR insulation

At a glance

When specifying IDELCO α-therm ROOF, identify what secures the insulation to the deck and what holds the waterproofing in place. These two interfaces can require different materials. On a bonded roof, both contact surfaces at each joint matter. Ballast adds weight, while mechanical fixing depends on the deck and anchorage. State the selected method alongside the roof section so the full cost can be calculated. It also allows inspection before the first covering layer conceals fasteners or bonded areas.

IDELCO α-therm ROOF insulation board with its facings

α-therm ROOF in a roof build-up

Label each interface from structure to covering. Ask the bidder to assign a material and installation method to each, including at the parapet.

Board resistance and whole-roof performance

The manufacturer gives α-therm ROOF a λD of 0.022 W/(m·K). Declared resistance is 4.50 m²K/W for the 100 mm board and 6.35 m²K/W for 140 mm.

The extra 40 mm raises RD by 1.85 m²K/W. Check the remaining height for waterproofing upstands and access to the outlet on the drawing.

Board format and edge profile

Boards are available in 1200 × 600 and 1200 × 2400 mm formats with square or rebated edges. Confirm the combination of dimensions, thickness and profile offered for the delivery.

Map the edges after cutting around a group of penetrations. Mark which pieces retain a rebate and which require the detail for a plain cut edge.

Mechanical fixing, bonding and ballast

A ballasted option requires a schedule of layer weights and a structural check. A bonded option needs evidence of adhesion to the deck and board facing in the specified system.

If fasteners are specified, check their type and length against the actual build-up. The fixing layout should cover corner and perimeter zones.

Product classification and end use

The sheet gives at least 150 kPa at 10% deformation and reaction to fire class F for the product. Use the compression value within the scope set by the roof designer.

A separate B-s2,d0 result concerns a specified application on steel decking. Compare the tested construction with the proposed substrate, orientation and protective layers before relying on that classification.

Specifying the exact board on the order

Use α-therm ROOF on the order. If the estimate refers to the older I-ROOF name, ask for the item to be matched to the current data sheet and product label.

For quotes with different securing methods, separate material, lifting and labour costs. In a ballasted option include delivery and distribution of the ballast itself.

What a bonded roof quote should identify

If the specification only says “bonded roof”, ask for a section through one corner. Identifying every bond, adhesive and substrate condition makes the scope buildable and inspectable.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide