Thermano Roof above the rafters: what to settle before the roof goes on

PIR insulation

At a glance

Above the rafters, Thermano Roof preserves headroom but raises the covering in relation to the eaves, chimney and roof windows. Before choosing a thickness, ask for sections through those junctions. They should show the insulation, the route rainwater takes and how loads reach the timber. The rigid PIR core and aluminium-containing facings on both sides describe the board; the roof still needs its own design. Details drawn for a pitched roof cannot simply be carried over to a flat roof, another application for Thermano Roof.

Thermano Roof insulation board showing the core and facing

Where the board fits in the project

Mark clear roof areas separately from rooflights, chimneys and valleys. Roof area alone tells the roofer little about the time needed for those junctions.

When reroofing, establish which flashings will still fit at the new height. Price removal, replacement flashings and temporary overnight weather protection separately.

Junctions worth checking

The usual overall size is 1200 × 2400 mm. Check whether the order specifies BASIC, TOP or MASTER edges: their geometry affects the joint layout.

Place a board outline over the roof window on the drawing. If it leaves a narrow strip, ask what will support it and whether shifting the row would avoid that cut.

Reading the thermal figures

Use the declared conductivity of Roof, 0.023 W/(m·K), when calculating the insulation resistance. At a given conductivity, resistance depends on thickness.

When comparing sections, ask for the thermal result for the roof including its fixings. A better compression test result does not make up for missing insulation thickness.

Protecting the layers and their junctions

Trace a raindrop on the section from the head of a roof window to the eaves. The board’s gas-tight facing does not replace the drainage layer.

Photograph the chimney detail once the flashing is in place and before it is concealed. A general photo of the finished covering cannot show where the lap discharges.

Understanding load and fire ratings

Thermano Roof is rated at least 200 kPa at 10% deformation, with TR100 tensile strength and reaction-to-fire class E. These describe three different properties.

For rooftop equipment, establish the load on each foot, its bearing area and its anchorage to the structure. The CS figure does not specify a permissible equipment weight.

Comparing the full scope of quotes

Compare quotes for the same board edge, thickness and number of openings. Establish who supplies the fixings and who specifies them.

Before accepting, total the roof area, linear metres of flashing and work at each window separately. This gives the cost of retaining loft space after the external alterations are included.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide