Choosing a mineral wool sandwich panel for your building

At a glance
A mineral wool sandwich panel combines metal facings and an insulating core for specific wall or roof applications. It is often considered where a design sets fire performance requirements. The word “wool” alone does not establish suitability: check the model, thickness, span, support type and documented classification of the complete assembly. Panel weight affects transport and installation, while acoustic requirements need their own assessment. This guide explains what to include in an order that matches the design. Figures for one model do not apply to every mineral wool panel or replace documentation for the batch supplied.
Reaction to fire and fire resistance
Reaction to fire describes a product’s contribution to fire development. Fire resistance describes how long a specified building element maintains integrity, insulation and, where relevant, loadbearing capacity. A2-s1,d0 and EI are not alternative ways of expressing the same result. Check the required class against the tested assembly, including thickness, orientation, permissible span, fixings and seals. Increasing thickness does not in itself justify assigning a higher EI rating.
Reading a product data table
The manufacturer’s 2026 catalogue gives a mass of 18.1 kg/m² and Uc = 0.39 W/(m²·K) for the 100 mm PWW-S wall panel with 0.5/0.5 mm facings. Its reaction to fire is A2-s1,d0. Different facing thicknesses, cores or panel families require their own data. Use the weight to plan unloading and lifting. Panel length and span between supports are different dimensions: for a long panel, check the structural drawings and load tables rather than assuming the delivery length is an allowable span.
Installation and moisture
Install joints, flashings and fasteners according to the chosen manufacturer’s instructions. Pay attention to the base, corners, openings and service penetrations. Do not replace the specified seals with a convenient general-purpose compound. At delivery, inspect the packaging, facings and edges. Arrange dry, protected storage as instructed. A damaged edge or wet core needs assessment; defects in second-grade panels are not necessarily cosmetic.
Mineral wool and acoustics
An ordinary mineral wool panel is not automatically a sound absorber. To reduce indoor reverberation, check for a perforated facing and a declared absorption rating. To limit sound passing through a wall, assess its sound insulation and the entire construction. See our guide to acoustic panels.
Preparing the order list
Specify the wall or roof, design requirements for heat and fire, panel lengths, quantities, facing thicknesses, colour and delivery location. Add flashings and fixings. Compare the complete package including unloading rather than the panel price per square metre.
Free quote
What to include in your enquiry
Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.
More from the building guide
Start a farm insulation survey by marking the spaces that need different conditions on a floor plan. In a vegetable store, air…
A wood-effect sandwich panel combines a decorative metal facing with the properties of its core and joint system. The grain describes the…
PIR sandwich panels form a building envelope from metal facings and an insulating core. Wall and roof panels differ in profile, joints…
Sandwich panels can form an enclosure over a masonry wall, provided the substrate, connections and complete build-up are assessed for the project.…
Sandwich-panel thickness is selected against thermal targets, loads and operating conditions. No single table converts a standard's name into a required number…
Support spacing for wall sandwich panels must be selected for the exact panel model and the building's loads. Core thickness alone is…
Sandwich panels can form part of a house's envelope, but their use requires a design for the whole building. Roof and wall…
Water on a sandwich panel can be condensation rather than a roof leak. Warm, moist air releases water when it meets a…