Choose a material

Roofing sheets

Blachy trapezowe

Sandwich panels

Płyty warstwowe

PIR insulation boards

Płyty izolacyjne PIR

XPS

Izolacja XPS

Accessories

Akcesoria montażowe

Fencing

Sztachety metalowe

How to compare warranties for integrated photovoltaic roofs

Roofing and energy

At a glance

The longest warranty in a solar roof quotation may cover only one feature. The coating, roofing element, PV module, retained output, inverter and installation work can each have different terms. Compare like with like. For each item identify the guarantor, covered defect, duration, exclusions, owner’s duties and remedy. On an integrated roof a module repair may involve opening the covering. Establish who pays for removal, temporary weather protection, transport, refitting and restoring weathertightness. Ask for the documents for the exact models being ordered so the headline period can be read alongside the costs and work it actually covers.

Dark photovoltaic fields alongside passive roofing elements

Why does the length alone tell you so little?

Compare the same items in each quotation, rather than ranking the offers by the largest number of years.

Request the full terms before placing the order. A brochure can omit conditions. A table listing the covered item, period, responsible party and remedy shows whether the offer provides for servicing the system or covers only a component characteristic.

How do product and power warranties differ?

A product warranty covers defects described in its terms. A power warranty relates to a specified module performance level over time under a defined measurement method. Annual energy yield also depends on weather, shade and the other equipment.

A retained power percentage does not translate into the same percentage of a household bill. Consumption and tariffs change. Check what evidence and testing a claim requires and what remedy is offered if the shortfall is confirmed.

How is the roofing function covered?

Ask which covering components, joints and flashings are covered and what installation conditions apply. A steel panel with cells serves weather protection and generation together. If it must be removed, identify who protects the opening during the work.

Read the provisions for dismantling, shipping and reinstallation. Supplying a replacement does not necessarily cover the whole operation. The method for reinstating the roof’s weather protection matters as much as the replacement module specification.

Which operating conditions matter?

The documents may specify installation instructions, maintenance methods or inspections. Check who may carry them out and which records to keep. Also check environmental restrictions for the coating and particular system configuration.

Agree later alterations with the responsible installer or supplier. Additional openings, equipment or unsuitable cleaning can affect the roof. The effect on a claim depends on the terms and the issue concerned. Keep written records of the agreement.

Who receives the report and arranges repairs?

A single service contact helps the owner, but identify the parties responsible for individual parts and keep their contact details. An integrated appearance does not imply the same guarantor or procedure for every device.

Ask what to submit and what happens next. Component numbers, pictures, messages and monitoring records can help. The procedure should provide for technical diagnosis and cooperation between trades without requiring the owner to identify the underlying fault.

What makes one offer more suitable?

Compare covered costs, service availability, owner obligations and duration for the actual models. Ask for clarification before installation if a quote describes whole-roof protection but the supplied terms refer only to a module.

Good warranty terms complement a well-designed and correctly installed roof. Clearly assigned responsibility helps the owner judge what the promised period means for future problems with the covering and the generating system.

Work through the replacement of one damaged panel with the bidder. For each step, from access to closing the roof, enter the relevant warranty clause in your comparison table. A blank cell identifies a cost or responsibility to clarify before purchase.

Companies and brands in roof-integrated photovoltaics include SoliTek, Dyaqua, SolRoof, SunRoof, MDM NT (MyRoof), ML System, Wienerberger Wevolt, Electrotile, Nelskamp and EDILIANS.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E
  • BŁONIE — ul. Sochaczewska 138A
  • RADOM — ul. Grobickiego 8
  • ŁÓDŹ — Natolin 8
  • OLSZTYN — Barczewo, ul. Prosta 9
  • WROCŁAW — ul. Jerzmanowska 10C
  • GORZÓW WLKP. — ul. Zielona 33/34
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide