Kingspan Therma TR27 beneath a bonded roof membrane

PIR insulation

At a glance

For a Therma TR27 roof, have the roofer name the membrane and adhesive in the quotation. The glass fleece facing is the contact surface for the next layer, so the bond must suit the particular system. Compare insulation thicknesses once the covering is defined. In the TR27 catalogue, both thermal resistance and declared conductivity vary. If a thicker board is selected, check the remaining room for membrane terminations at corners, parapets and flashings.

Therma TR27 roof board with its glass fleece facing

The two connections in the roof build-up

Show the attachment of TR27 to the deck separately from the attachment of the covering to the board. Specify each connection.

If a different adhesive is proposed, confirm compatibility with the fleece and membrane underside. Establish the permitted temperature and moisture conditions during application.

Inspecting edges and corners

Standard TR27 measures 1200 × 600 mm. The catalogue lists square and profiled edges. Check that the delivered edge matches the cutting layout.

Trial-fit the last board at a corner before bonding. It should sit steadily without lifting the edge below the future flashing junction.

Thickness-specific TR27 figures

The Polish catalogue lists λD 0.027 W/(m·K) and RD 3.70 m²K/W at 100 mm. At 120 mm it gives 0.026 W/(m·K) and 4.60 m²K/W respectively.

The difference between these entries is 0.90 m²K/W. Check this against the thermal target and the extra 20 mm of build-up at the flashings.

Surface condition before bonding

Before covering, inspect any surface showing signs of wetting or delamination. Use the selected system instructions to decide how to handle a damaged facing.

Where the system requires an adhesion check, record the location, conditions and result. This preserves evidence of the surface condition after the roof is closed.

Service loads and board properties

TR27 is declared at least 120 kPa at 10% deformation and has reaction to fire class E. Assess roof capacity and assembly fire classification separately.

For the maintenance route, specify traffic frequency and protection above the membrane. Foot traffic and a permanent machine support impose different loads.

Pricing a complete bonded roof

Compare roof costs at the same target U-value. List boards, adhesives, ancillary layers and substrate preparation labour individually.

If one quote covers only the field, add perimeters and corners using the same details as the second quote. This gives comparable completed roof costs.

7 branches. Materials closer to your project.

  • SEROCK — Dzierżenin 34 E [mapa]
  • BŁONIE — ul. Sochaczewska 138A [mapa]
  • RADOM — ul. Grobickiego 8 [mapa]
  • ŁÓDŹ — Natolin 8 [mapa]
  • OLSZTYN — Barczewo, ul. Prosta 9 [mapa]
  • WROCŁAW — ul. Jerzmanowska 10C [mapa]
  • GORZÓW WLKP. — ul. Zielona 33/34 [mapa]
Budowlanka.org — map

Free quote

What to include in your enquiry

Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.

More from the building guide