Short of space for insulation? Assessing termPIR MAX 19 AL
PIR insulation
A low threshold or an existing eaves flashing can limit insulation depth. termPIR MAX 19 AL combines a rigid PIR core with gas-tight facings of aluminium, paper and polyethylene. Its low conductivity can reduce the thickness needed to meet a given layer resistance. The useful question is whether that saving lets you retain the threshold or flashing. Draw the finished section with each proposed board, allowing for support, adjoining layers and fixings. If both options fit without rebuilding, compare the remaining requirements and the full installed price before paying a premium.

Identify the detail that needs the space
Measure the depth below the flashing after deducting every layer except insulation. Identify what would need rebuilding if the board did not fit. Low conductivity changes thickness, not substrate condition or the flashing junction.
Ask for two dimensioned sections rather than two totals. If neither requires a change to the existing opening or flashing, compare cost, load suitability and installation details on their merits.
What to look for at a joint
On a MAX 19 AL sample, TAG denotes a tongue-and-groove joint, LAP a shiplap and FIT a square edge. Match the sample to the ordered designation.
Trial-fit two boards over the uneven area. If the joint closes only under pressure, inspect flatness and support rather than forcing it. Record edge condition and any residual gap before covering.
Translate the thermal target into a stock size
The declared λD of 0.019 W/(m·K) for MAX 19 AL applies from 80 to 220 mm. Respect that range even when a preliminary calculation produces an unusual thickness.
For R = 5.0 m²K/W, 5.0 × 0.019 gives 0.095 m, or 95 mm. This is a calculation, not a guarantee of a 95 mm stock size. Choose an available thickness that meets the target, verify its declared resistance and recalculate the complete assembly.
Protect boards and vapour-control junctions
Provide dry storage and temporary protection before delivery. The gas-tight face resists vapour across the laminate; it does not provide a factory seal between adjacent boards.
At a perimeter penetration, show how the facing meets the wall seal. Inspect it before covering and protect the open edge overnight. A lambda of 0.019 cannot stop air passing through an open joint.
Check compression and fire separately
This variant declares CS(10/Y)100 and reaction-to-fire class E. Do not substitute CS120 from a different silver-faced board.
Check the required thermal resistance, equipment loads and fire requirements independently. Saving space at the threshold addresses the first. Keep the exact variant’s documentation and the assembly assessment for the others.
Compare the cost of keeping the existing geometry
Compare 600 × 1,200 and 1,200 × 2,400 mm layouts. Adjust nominal area for the edge profile and compare prices at the same thermal target.
Separate alteration of the threshold or flashing, fixings and finishes in both estimates. The difference in the finished detail shows whether the higher board price avoids other costs. Include effective coverage and cuts for both layouts.
Free quote
What to include in your enquiry
Tell us how you plan to use the material, the dimensions and the quantity you need. Include the thickness, grade or variant name, along with the delivery town or your preferred collection branch. For a specific product, add its name or a link to the product page. We will reply to the email address you provide to discuss availability and the terms of your order.
More from the building guide
Thermano ETICS combines foil-faced PIR with 20 mm of external façade-grade EPS. The following system layers meet the EPS, not the foil…
Planning PIR insulation should begin by identifying which rooms will belong to the heated part of the house. The roof, a ceiling…
For over-rafter Powerroof insulation, count boards by their covering dimensions, not their transport size. A 2400 × 1200 mm board covers 2380…
The amount of waste when insulating with PIR boards also depends on measurement, the layout of elements and the organisation of delivery.…
A terrace above a heated room forms part of the building's roof, while a canopy over the terrace shelters the seating area…
Effective roof insulation forms a continuous boundary around heated rooms, rather than merely a thick layer across the middle of a slope.…
When choosing swissporPIR Alu, look at a section through two joined boards. FIT/GK has square edges, LAP/SF forms a rebated joint, and…
When damp repeatedly appears at home, gather organised observations before choosing a repair. A mark beside a window, a wet corner and…