Panels · Sheet metal · Insulation · Accessories

swissporPIR Alu edges: square, rebated or tongue and groove?

When choosing swissporPIR Alu, look at a section through two joined boards. FIT/GK has square edges, LAP/SF forms a rebated joint, and a TAG/NuF tongue fits into the neighbouring groove. The difference matters in the last row: trimming a board against a wall can remove the factory edge you need for the next joint. Check the laying direction, cuts and coverage before ordering. A shaped edge helps the boards fit together; the design must still provide support and waterproofing.

By |2026-11-12T17:03:44+01:0012 November 2026|PIR boards and insulation|Comments Off on swissporPIR Alu edges: square, rebated or tongue and groove?

Choosing swissporPIR Alu for a house: thickness, joints and loads

swissporPIR Alu is a PIR insulation board with a laminated facing. Its silver surface does not make it a self-supporting roof panel or a finished roof covering. When buying it for a house, check the thermal resistance of the chosen thickness, a board size that fits the layout, and the loading it will see in service. Pay particular attention where a pipe crosses the junction between a wall and roof: a value from the product declaration cannot tell you whether the insulation will be continuous at that corner.

By |2026-11-12T16:44:50+01:0012 November 2026|PIR boards and insulation|Comments Off on Choosing swissporPIR Alu for a house: thickness, joints and loads

Choosing Kingspan insulation for a house: identify the board before comparing prices

If a contractor offers a “Kingspan board or equivalent”, start by asking for the full product name and its intended position. Therma is a PIR insulation range, Kooltherm has a phenolic core, and sandwich panels with structural facings perform a different job again. Even two Therma roofing boards of equal thickness need not have the same thermal resistance or facing. TR26 and TR27 illustrate how to check what a substitution would mean for roof height, attachment of the waterproofing and the installed price.

By |2026-11-12T16:44:49+01:0012 November 2026|PIR boards and insulation|Comments Off on Choosing Kingspan insulation for a house: identify the board before comparing prices

Therma TF70 under a house floor: levels, service chases and screed

Therma TF70 is a PIR board for floor insulation. In a house with a low patio threshold, work down from the finished floor level: the screed, any heating system and the floor finish all need space as well as the insulation. Before the boards hide the services, agree how they will be supported over chases and at the wall. Comparing 80 and 100 mm boards shows what an extra two centimetres buys in thermal resistance and why the floor load capacity cannot be read from one PIR rating.

By |2026-11-12T16:44:47+01:0012 November 2026|PIR boards and insulation|Comments Off on Therma TF70 under a house floor: levels, service chases and screed

Therma TT46 on a flat roof: tracing the route to the outlet

To specify Kingspan Therma TT46 tapered boards, trace the water from the high point of the roof to its outlet. Mark the chimney, parapets and actual outlet level on a roof plan. Follow the proposed route on either side of each obstruction: where does each branch discharge? This guide explains how to read the direction and rise of a board, why its thickest edge does not represent the insulation across the whole roof, and which setting-out information the installer needs with the delivery.

By |2026-11-12T16:44:46+01:0012 November 2026|PIR boards and insulation|Comments Off on Therma TT46 on a flat roof: tracing the route to the outlet

Kingspan Therma TR27 beneath a bonded roof membrane

For a Therma TR27 roof, have the roofer name the membrane and adhesive in the quotation. The glass fleece facing is the contact surface for the next layer, so the bond must suit the particular system. Compare insulation thicknesses once the covering is defined. In the TR27 catalogue, both thermal resistance and declared conductivity vary. If a thicker board is selected, check the remaining room for membrane terminations at corners, parapets and flashings.

By |2026-11-12T16:44:45+01:0012 November 2026|PIR boards and insulation|Comments Off on Kingspan Therma TR27 beneath a bonded roof membrane

Kingspan Therma TR26 on a flat roof with rooflights

For a roof with several rooflights, order Therma TR26 from a plan showing the kerb dimensions. Total roof area misses the short runs and narrow strips between openings. Draw the board joints and check that the insulation has a supported termination and room for the waterproofing upstand at each kerb. Mark service penetrations at the same time. The drawing then helps you select a board size, estimate cutting waste and agree the roofer’s scope at each opening.

By |2026-11-12T16:44:44+01:0012 November 2026|PIR boards and insulation|Comments Off on Kingspan Therma TR26 on a flat roof with rooflights

IDELCO α-therm SIP: what makes an insulated panel structural?

For a wall built from IDELCO α-therm SIP panels, fix window and door positions on the fabrication drawings. Loads are carried by the designed combination of core, structural facings and connections. Cutting an extra opening on site can change how the entire wall behaves. A thinly laminated PIR insulation board serves a different purpose. Before ordering, give the engineer the opening dimensions, service routes and base support detail. These inputs determine the schedule of panels ready for installation.

By |2026-11-12T16:44:43+01:0012 November 2026|PIR boards and insulation|Comments Off on IDELCO α-therm SIP: what makes an insulated panel structural?

IDELCO AGRO+ for farm buildings: choosing lengths, facings and edge profiles

Start an IDELCO AGRO+ order by measuring the route the longest board must take from the lorry to the ceiling. A made-to-length piece can reduce joints, but it still has to pass through the door, turn and remain supported during installation. Mark strip lengths, profiles and the visible face on the ceiling plan. Agree the operating conditions too, including cleaning and moisture removal. This checks both the dimensions and the suitability of the finish before production.

By |2026-11-12T16:44:42+01:0012 November 2026|PIR boards and insulation|Comments Off on IDELCO AGRO+ for farm buildings: choosing lengths, facings and edge profiles

IDELCO α-therm SARKING on a pitched roof: planning from eaves to ridge

Before adding IDELCO α-therm SARKING above rafters, draw the eaves with the existing gutter. Raising the covering changes where water leaves the slope. The roofing underlay needs its own drainage path. The board laminate has no roofing membrane laps, so list insulation, underlay, counterbattens and flashings separately. On the same section check the junction with wall insulation and the height of the first batten. The roofer can then price alterations to the eaves for the actual board thickness.

By |2026-11-12T16:44:41+01:0012 November 2026|PIR boards and insulation|Comments Off on IDELCO α-therm SARKING on a pitched roof: planning from eaves to ridge
Back to top