Panels · Sheet metal · Insulation · Accessories

A SOPREMA PIR roof at a rooflight: who completes each layer?

Three layers meet a rooflight kerb. EFYOS BLUE A insulation must reach it as shown on the thermal detail. The vapour control layer needs a connection on the side specified by the designer, while the waterproofing must return rainwater to the roof surface. If different trades install the layers, mark the trade and inspection point for each connection on a single section. Inspect during installation. Once the final membrane is in place, two of the three connections are generally concealed.

By |2026-11-12T16:04:45+01:0012 November 2026|PIR boards and insulation|Comments Off on A SOPREMA PIR roof at a rooflight: who completes each layer?

EFIGREEN ITE on an external wall: will the existing sill still fit?

To decide whether an existing sill will work with SOPREMA EFIGREEN ITE, measure its projection from the future façade face. On a window section mark the masonry, PIR, support frame, space behind the cladding, cladding thickness and frame position. Include the sill ends. The section shows how much insulation fits at the reveal and where rain drains clear of the wall. Select board thickness alongside this window detail. Replacing a short sill later can involve removing part of the new cladding.

By |2026-11-12T16:04:44+01:0012 November 2026|PIR boards and insulation|Comments Off on EFIGREEN ITE on an external wall: will the existing sill still fit?

EFIGREEN ALU+ or ALU+ XL for a roof with service penetrations?

Use the same roof drawing to prepare two cutting layouts for EFIGREEN ALU+ and ALU+ XL. Larger sheets reduce the joint count on a clear deck. Between vent pipes and equipment bases, smaller 600 × 600 mm boards may allow more pieces to be laid whole. The result depends on spacing, laying direction and the size of the specific XL version. Check the thickness and product designation on both quotes, then compare quantities, waste and work at penetrations for each layout.

By |2026-11-12T16:04:43+01:0012 November 2026|PIR boards and insulation|Comments Off on EFIGREEN ALU+ or ALU+ XL for a roof with service penetrations?

EFYOS BLUE SMART A on a small roof: drawing the falls around a rooflight

When a puddle forms beside a rooflight, survey the levels between its kerb and the outlet first. They show whether the kerb obstructs drainage and where an EFYOS BLUE SMART A tapered board is needed. On a small roof a few centimetres can move the low point. Draw flow arrows, the outlet level, valley line and transitions to flat insulation. The roofer can then schedule pieces in laying order and check that the waterproofing can terminate at the required height on the kerb.

By |2026-11-12T16:04:42+01:0012 November 2026|PIR boards and insulation|Comments Off on EFYOS BLUE SMART A on a small roof: drawing the falls around a rooflight

SOPREMA EFYOS BLUE A: checking parapet height before ordering

On a flat roof using SOPREMA EFYOS BLUE A, start at the tightest detail: what height remains at the parapet once insulation and waterproofing are in place? Survey existing levels and mark the fall and flashing termination on a section before comparing thicknesses. The product sheet gives resistance for individual board variants, not the U-value of the finished roof. The order also needs an edge type, net covering area and confirmation that the selected waterproofing can be installed on this substrate.

By |2026-11-12T15:45:33+01:0012 November 2026|PIR boards and insulation|Comments Off on SOPREMA EFYOS BLUE A: checking parapet height before ordering

Eurothane G in a flat: what to inspect before lining the wall

Recticel Eurothane G combines PIR with gas-tight facings on both sides and a 12.5 mm plasterboard lining. In a flat renovation it provides insulation and a finishing surface in one panel. Before covering the masonry, establish whether it is dry, how moisture behaves at floor junctions and how the reveals will be insulated. Panel depth also affects radiators, sockets and usable room width. Measure those clearances using the full lining thickness rather than the PIR core alone.

By |2026-11-12T15:45:32+01:0012 November 2026|PIR boards and insulation|Comments Off on Eurothane G in a flat: what to inspect before lining the wall

Powerdeck F on a flat roof: how to check the fleece-facing bond

Start a Recticel Powerdeck F specification with the roof covering: identify the membrane, attachment method and substrate it requires. The board has a fleece facing, so a foil-faced board of similar thickness is not automatically interchangeable. For a bonded system, confirm compatibility of the precise membrane, adhesive and board surface. Size the insulation separately using λD 0.026 W/(m·K). Check a parapet section for enough space to terminate the waterproofing at the finished level.

By |2026-11-12T15:45:30+01:0012 November 2026|PIR boards and insulation|Comments Off on Powerdeck F on a flat roof: how to check the fleece-facing bond

Powerroof above the rafters: how much roof does one board cover?

For over-rafter Powerroof insulation, count boards by their covering dimensions, not their transport size. A 2400 × 1200 mm board covers 2380 × 1180 mm once the tongue and groove engage: about 2.81 m² per full board in the main roof area. Valleys, chimneys and windows change the yield. Draw rows and cuts for each slope before ordering. Also check an eaves section: over-rafter insulation preserves loft headroom but changes the level of the covering and its terminations.

By |2026-11-12T15:45:29+01:0012 November 2026|PIR boards and insulation|Comments Off on Powerroof above the rafters: how much roof does one board cover?

Eurothane Silver on a flat roof: specify thickness, edges and waterproofing

Changing Eurothane Silver thickness can change more than the insulation value. The 20 mm version has different format options and compressive performance from thicker boards. Before accepting a substitute, match the label to the roof drawing: board size, edge, thickness and waterproofing attachment all matter. Check finished levels at the parapet and outlet. Matching conductivity alone does not show that the proposed alternative will fit the designed details.

By |2026-11-12T15:45:28+01:0012 November 2026|PIR boards and insulation|Comments Off on Eurothane Silver on a flat roof: specify thickness, edges and waterproofing

Eurofloor beneath underfloor heating: work back from the finished floor level

Before ordering Eurofloor, measure from the base to finished floor level at the lowest threshold. Insulation, heating pipes, screed and finish must share that space. The PIR board limits heat flow downwards; the complete floor section determines whether a given thickness fits. Mark heavy furniture and appliances, and agree how boards will be protected until covered. Pack prices alone tell you little about differences in the proposed floor construction.

By |2026-11-12T15:45:27+01:0012 November 2026|PIR boards and insulation|Comments Off on Eurofloor beneath underfloor heating: work back from the finished floor level