EFYOS BLUE SMART A on a small roof: drawing the falls around a rooflight

When a puddle forms beside a rooflight, survey the levels between its kerb and the outlet first. They show whether the kerb obstructs drainage and where an EFYOS BLUE SMART A tapered board is needed. On a small roof a few centimetres can move the low point. Draw flow arrows, the outlet level, valley line and transitions to flat insulation. The roofer can then schedule pieces in laying order and check that the waterproofing can terminate at the required height on the kerb.

By |2026-11-12T16:04:42+01:0012 November 2026|PIR boards and insulation|Comments Off on EFYOS BLUE SMART A on a small roof: drawing the falls around a rooflight

SOPREMA EFYOS BLUE A: checking parapet height before ordering

On a flat roof using SOPREMA EFYOS BLUE A, start at the tightest detail: what height remains at the parapet once insulation and waterproofing are in place? Survey existing levels and mark the fall and flashing termination on a section before comparing thicknesses. The product sheet gives resistance for individual board variants, not the U-value of the finished roof. The order also needs an edge type, net covering area and confirmation that the selected waterproofing can be installed on this substrate.

By |2026-11-12T15:45:33+01:0012 November 2026|PIR boards and insulation|Comments Off on SOPREMA EFYOS BLUE A: checking parapet height before ordering

Eurothane G in a flat: what to inspect before lining the wall

Recticel Eurothane G combines PIR with gas-tight facings on both sides and a 12.5 mm plasterboard lining. In a flat renovation it provides insulation and a finishing surface in one panel. Before covering the masonry, establish whether it is dry, how moisture behaves at floor junctions and how the reveals will be insulated. Panel depth also affects radiators, sockets and usable room width. Measure those clearances using the full lining thickness rather than the PIR core alone.

By |2026-11-12T15:45:32+01:0012 November 2026|PIR boards and insulation|Comments Off on Eurothane G in a flat: what to inspect before lining the wall

Powerdeck F on a flat roof: how to check the fleece-facing bond

Start a Recticel Powerdeck F specification with the roof covering: identify the membrane, attachment method and substrate it requires. The board has a fleece facing, so a foil-faced board of similar thickness is not automatically interchangeable. For a bonded system, confirm compatibility of the precise membrane, adhesive and board surface. Size the insulation separately using λD 0.026 W/(m·K). Check a parapet section for enough space to terminate the waterproofing at the finished level.

By |2026-11-12T15:45:30+01:0012 November 2026|PIR boards and insulation|Comments Off on Powerdeck F on a flat roof: how to check the fleece-facing bond

Powerroof above the rafters: how much roof does one board cover?

For over-rafter Powerroof insulation, count boards by their covering dimensions, not their transport size. A 2400 × 1200 mm board covers 2380 × 1180 mm once the tongue and groove engage: about 2.81 m² per full board in the main roof area. Valleys, chimneys and windows change the yield. Draw rows and cuts for each slope before ordering. Also check an eaves section: over-rafter insulation preserves loft headroom but changes the level of the covering and its terminations.

By |2026-11-12T15:45:29+01:0012 November 2026|PIR boards and insulation|Comments Off on Powerroof above the rafters: how much roof does one board cover?

Eurothane Silver on a flat roof: specify thickness, edges and waterproofing

Changing Eurothane Silver thickness can change more than the insulation value. The 20 mm version has different format options and compressive performance from thicker boards. Before accepting a substitute, match the label to the roof drawing: board size, edge, thickness and waterproofing attachment all matter. Check finished levels at the parapet and outlet. Matching conductivity alone does not show that the proposed alternative will fit the designed details.

By |2026-11-12T15:45:28+01:0012 November 2026|PIR boards and insulation|Comments Off on Eurothane Silver on a flat roof: specify thickness, edges and waterproofing

Eurofloor beneath underfloor heating: work back from the finished floor level

Before ordering Eurofloor, measure from the base to finished floor level at the lowest threshold. Insulation, heating pipes, screed and finish must share that space. The PIR board limits heat flow downwards; the complete floor section determines whether a given thickness fits. Mark heavy furniture and appliances, and agree how boards will be protected until covered. Pack prices alone tell you little about differences in the proposed floor construction.

By |2026-11-12T15:45:27+01:0012 November 2026|PIR boards and insulation|Comments Off on Eurofloor beneath underfloor heating: work back from the finished floor level

Thermano ETICS beneath render: which side receives the finish?

Thermano ETICS combines foil-faced PIR with 20 mm of external façade-grade EPS. The following system layers meet the EPS, not the foil on the core. For a house project, check the total composite thickness, the resistance of that version and the specification for the complete render system. A section through a window is a good place to compare options: it shows the sill projection, the reveal and the detail that sheds water clear of the finished façade.

By |2026-11-12T15:45:26+01:0012 November 2026|PIR boards and insulation|Comments Off on Thermano ETICS beneath render: which side receives the finish?

Thermano GK-A or GK-H2: choosing an internal lining by room

Thermano GK-A and GK-H2 combine a PIR core with 12.5 mm plasterboard. White type A is for ordinary dry rooms; green H2 has reduced water absorption. Choose by how the particular wall is used. A shower splash zone needs different protection from a surface outside the spray. Assess the masonry before buying: internal insulation changes its temperature and drying potential. The colour of the lining does not tell you whether a damp wall can be covered.

By |2026-11-12T15:45:25+01:0012 November 2026|PIR boards and insulation|Comments Off on Thermano GK-A or GK-H2: choosing an internal lining by room

Thermano Compact for a small renovation: start with the cutting plan

Thermano Compact boards measure 600 × 1200 mm, a useful size for narrow stairs and a job made up of short runs. Measure the access route, the longest piece required and the space available for cutting as well as the recess itself. Draw the pieces on a full board outline. That sketch will tell you how many boards to buy and which factory edges will survive the cut. Thickness and the loads the insulation must carry are separate decisions.

By |2026-11-12T15:45:23+01:0012 November 2026|PIR boards and insulation|Comments Off on Thermano Compact for a small renovation: start with the cutting plan